BE ORIGINATIVE NICHIRYO

ISO9001ISO14001

  • About NICHIRYO AMERICA
  • Environment
  • NICHIRYO GLOBAL SITE

Nichipet EX Plus A value added Nichipet EX PDF Download

FEATURES

  • This is the new mechanism and value added Nichipet EX with popular features.
  • Advanced durability against organic solvent dispensing.
    Perfluoro rubber O-ring has been installed as standard option.
    The durability of air sealing is enhanced in time of organic solvent dispensing.

    *The Perfluoro rubber is a material of low cubical expansion against organic solvents and can keep its performance over the long term compared to fluorocarbon rubber.
    *Note that this feature does not guarantee dispense accuracy of an organic solvent.

Chemicals Temperature Fluorine rubber Test days Perfluoro rubber
Organic acid
Gracial acetic acid 40°C 8 A C
Acetic auhydride 40°C 8 A C
Inorganic alkalies
28% Ammonia water 40°C 21 A D
Ketone, Ester, Ether
Acetone 40°C 21 B D
Diacetone 40°C 21 A C
Acetylacetone 40°C 21 A D
Methyl acetoacetate 40°C 21 A C
Acrylic acid 40°C 21 A C
Diethyl oxalate 40°C 21 A D
Diethyl ether 25°C 21 B C

Chemicals Temperature Fluorine rubber Test days Perfluoro rubber
Furan,Aldehyde
Acetaldehyde 25°C 21 B D
Acetophenone 40°C 21 A C
Inclusive nitrogen compound
Acrylic nitrile 40°C 21 A C
Ethylene diamine 40°C 21 B D

A:Cubical expansion rate below 5%..... No problem at all
B:Cubical expansion rate 5%~20%..... No problem
C:Cubical expansion rate below 20%~50%..... Possible with some conditions
D:Cubical expansion rate over 50%..... Nonusable

  • Easy calibration mechanism
    Major modification of internal mechanism for easy calibration

    *We do not certify calibration done outside by users.
    *For certified calibration,Nichipet Ex Plus must be returned to our factory or our certified distributors.

  • ISO8655 Calibration Certificate attached
    Including ISO8655 Calibration Certificate sheet
  • Unchanged features
    Totally autoclavable (121°C 20minutes) Enhanced UV resistance
¦Ordering Information
Cat. No. Volume
range
Measured volume AC% CV% Increments
(µl)
Usable tips
Bulk Racked
NPLO-2 0.1~2µl 0.2µl 1µl 2µl ±12.0 ±5.0 ±3.0 <6.0 <2.5 <1.0 0.002µl BMT-UT BMT-UTR
NPLO-10 0.5~10µl 1µl 5µl 10µl ±4.0 ±1.0 ±1.0 <3.0 <1.0 <0.5 0.01µl BMT-SS BMT-SSR
NPLO-20 2~20µl 2µl 10µl 20µl ±5.0 ±1.0 ±1.0 <3.0 <1.0 <0.4 0.02µl BMT-SE,SG BMT-SER,SGR
NPLO-100 10~100µl 10µl 50µl 100µl ±2.0 ±1.0 ±0.8 <1.0 <0.3 <0.3 0.1µl BMT-SE,SG BMT-SER,SGR
NPLO-200 20~200µl 20µl 100µl 200µl ±1.0 ±0.8 ±0.8 <0.5 <0.3 <0.2 0.2µl BMT-SE,SG BMT-SER,SGR
NPLO-1000 100~1000µl 100µl 500µl 1000µl ±1.0 ±0.8 ±0.7 <0.5 <0.3 <0.2 1µl BMT-L BMT-LR
NPLO-5000 1000~5000µl 1000µl 2500µl 5000µl ±1.0 ±0.8 ±0.6 <0.3 <0.3 <0.2 10µl BMT-X BMT-XR
NPLO-10ML 1000~10000µl 1000µl 5000µl 10ml ±2.0 ±0.8 ±0.4 <0.4 <0.3 <0.2 10µl BMT-Z -

*The AC and CV values below 0.2µ by NPLO-2 largely depend on the operator's skill and the environment under which the pipette is used.
*The AC and CV values are the values by use of the disposable tip described on this site.
*The specification and price are subjected to change due to modification for quality improvement without notice.

Products TOP Page TOP